Ayat Contracting Inc.

Ayat Contracting Inc. provides roofing, masonry, waterproofing, concrete, and Local Law 11 (FISP) compliance services to building owners and property managers across all five NYC boroughs.
1151 East 58th Street, Brooklyn, NY 11234, USA
Phone:+1 347 330 3057 Price Range:$$
basement contractors

Local Law 126 Parking Garage Inspection Services

Certified QPSI parking garage inspections — meet Local Law 126 deadlines fast.

Home / Service/Local Law 126 Parking Garage Inspection Services​/

 

Local Law 126 Parking Garage Inspection Services in NYC

Local Law 126 of 2021 requires owners of parking garages and open parking structures in New York City to have their structures inspected by a Qualified Parking Structure Inspector (QPSI) and the findings filed with the Department of Buildings. Ayat Contracting Inc. provides QPSI inspection services along with the structural repair work that follows, so building owners can move from inspection to compliance without coordinating two separate contractors.

Request a Local Law 126 Inspection or call 347-330-3057.

What Is Local Law 126?

Local Law 126 of 2021 (codified as Article 323 of Title 28 of the NYC Administrative Code, and RCNY §103-13) established the city’s Periodic Inspection of Parking Structures (PIPS) program. It requires most parking garages and open parking structures — with limited exceptions for small lots, one- or two-car garages, and auto service stations — to undergo structural inspection by a QPSI on a recurring cycle, with findings filed to the DOB.

Key Deadlines and Filing Cycle

Every covered parking structure must complete an initial inspection by January 1, 2028, and be reinspected at least once every six years after that. Filing windows are phased by borough and community district, meaning your building’s specific deadline depends on its location — some districts (including parts of lower and western Manhattan) had earlier filing windows already open, while others are still ahead. We help determine which filing window applies to your building as part of the initial assessment.

What a QPSI Inspection Involves

A Qualified Parking Structure Inspector evaluates the structural condition of the garage — looking for issues like concrete spalling, reinforcement corrosion, deck deterioration, and drainage failures that are common in parking structures due to constant vehicle load, exposure, and deicing salt exposure in winter months. Following the inspection, a formal condition assessment report is filed with the DOB documenting the findings and, where applicable, required corrective action.

What Happens If a Structure Is Found Unsafe

If an inspection identifies an unsafe condition, the law generally requires it to be corrected within 90 days unless the QPSI determines a different timeframe is necessary and documents it in the filed report. Depending on severity, this can mean anything from cordoning off an affected area to more extensive structural repair before the space can be used normally again.

Penalties for Missing a Filing

Failing to file a required inspection within your building’s window can result in an initial civil penalty around $5,000, followed by continued monthly penalties of roughly $1,000 until the filing is completed. Given the citywide demand for a limited pool of certified QPSIs as deadlines approach, scheduling early is the most effective way to avoid a last-minute compliance scramble.

Our Local Law 126 Process

  1. Applicability & deadline review — confirming whether your structure is covered and which borough filing window applies
  2. QPSI inspection — full structural assessment of the parking structure by our certified inspector
  3. DOB filing — submitting the condition assessment report as required under RCNY §103-13
  4. Repair & remediation — completing any required structural repairs identified in the inspection, on the timeline the report specifies
  5. Re-filing & sign-off — documentation confirming the structure is back in compliant condition

Why Choose Ayat Contracting for Local Law 126 Compliance

Handling both the QPSI inspection and the repair work under one contractor means no gap between “here’s what’s wrong” and “here’s it fixed” — no re-scoping delays waiting on a second company to review someone else’s report. Every project includes a written scope and transparent pricing before repair work begins.

Frequently Asked Questions

Does my parking structure need a Local Law 126 inspection?

Most enclosed and open parking structures in NYC are covered, with limited exceptions for very small lots, one- or two-car garages, and auto service stations or showrooms. We can confirm applicability for your specific property during an initial review.

What’s the deadline for my building?

All covered structures must complete an initial inspection by January 1, 2028, but filing windows open earlier depending on borough and community district — some are already open. We determine your specific window as part of the applicability review.

What’s the difference between Local Law 126 and Local Law 11?

They’re separate laws covering different structures. Local Law 11 (FISP) governs facade inspection for buildings six stories or taller. Local Law 126 governs structural inspection specifically for parking garages and open parking structures, regardless of building height.

What happens after the QPSI files the report?

If the structure is found safe, the filing is complete until the next six-year cycle. If unsafe conditions are found, repair work generally needs to be completed within 90 days (or the timeframe specified in the report), followed by re-filing to confirm compliance.


Request a Local Law 126 Inspection or call 347-330-3057.

 

      SERVICES


            • BRICK REPOINTING
           
            • BASEMENT & FOUNDATION WALLS WATERPROOFING
           
            • WINDOW & WINDOWS LINTEL REPLACEMENT
           
            • CAULKING & SEALANT APPLICATION
           
            • LEAK INVESTIGATION
           
            • BALCONIES, TERRACES, PARKING LOTS & GARAGES
           
            • FLASHING LIQUID-APPLIED WATERPROOFING & TRAFFIC
           
            • AIR & VAPOUR BARRIERS
           
            • LOCAL LAW 11 (FISP)
           
           

Why Choose Ayat Contracting Inc.?

building restoration solutions


Contact for Services